Upper and lower double smoke inlets, zero fume escape
New Kitchen Choice for Young People | Marssenger Q36 Series Integrated Stove
Ocean Wave Aesthetics
|
|
| Upper and Lower Smoke InletsDouble smoke inlets built up strong defense line, capturing smoke effectively. |
Smart TrackingAdvanced AI Control Algorithms: It proactively senses flue resistance and intelligently adjusts suction power in real time. From the first sizzle to the final dish, it ensures not a single trace of smoke is left behind. |
|
| 1-Second Smoke Clearance: Powerful PerformancePowered by a 3rd-Gen BLDC inverter motor, it actively tracks and eliminates smoke in real time.
|
2-Star Sterilization CertificationOzone + ultraviolet double strong disinfection, disinfection rate of 99.99%, the national standard two-star certification, build a healthy line of defense tableware. |
|
| Extra Large CapacityUpper 57L Sterilizer + Lower 57L Dish Storage Cabinet, 114L large volume, can hold 102 pieces of standard tableware. |
Drying at a constant temperature of 60°CCompared with the high temperature drying on the market, Marssenger medium temperature drying does not hurt the dishes, more suitable for baby bottles, plastic products sterilization and drying needs. |
|
| Wide Leveling Technology
|
Upper air-inlet burner, no dead space for cleaningNew upward air inlet combustion system, one-piece molding seamless stove head, do not worry about foreign objects falling, a wipe is clean, good cleaning. |
|
| 11 levels of securityThe Galaxy platform is equipped with a new 11-step safety protection system for safe cooking and peace of mind. |
| Gas cooking stove | |||
| Gas type: | Liquefied gas | Petroleum | |
| Rated pressure (Pa): | 2800 | 2000 | |
| Rated thermal pressure (KW): | Left 4.5/Right 4.5 | Left 5.2/Right 5.2 | |
| Range hoods | |||
| Supply voltage (V): | 220 | Motor rated input power (W): | 400 |
| Frequency (Hz): | 50 | Air volume(m3/min): | 18 |
| Maximum static pressure (Pa): | 1100 | Noise (A sound power, dB): | 64 |
| Motor rated input power (W) | 250 | Air volume of bursting gear (m3/min): | 20 |
| Lighting power (W): | 6 | ||
| Sterilizer | |||
| Drying temperature (℃): | ≤60 | Sterilizer input power (W): | 515 |
| UV lamp power (W): | 18 | Heater input power (W): | 500 |
| Sterilizer volume (L): | 57(±10%) | UV wavelength (NM): | 253.7 |
| Sterilization stars: | ★★ | Sterilization methods: | Ozone/UV |
| Ozone concentrations(mg/m3): | ≥40 | Bowl rack load capacity (kg) | 6(±10%) |
| Total rated input power (W) for double gas glass sterilizer models: | 770 | ||